|
Manufacturer and Distributor of
Innovative
Text
Message Networking Center
Software
Multiple Sign Connectivity
Text
Display PLC Compatible & Networked Industrial Signaling
Products.
Message Center is designed for
installation in company lobbies to greet guests and provide them with
information at a glance. Such information may include meeting room assignments,
safety goals, changes in employee benefits or other company announcements. May
also be used in commercial establishments such as stores and restaurants to
assist with internal and external communications
MCN-2-0
Message Networking Center Software
Multiple Sign Connectivity

Application/Installation:
System Requirements
- MS/PS DOS 486 or compatible computer (a Pentium PC
is recommended for optimal performance) or a Macintosh
PowerPC
- 3.5 inch floppy diskette drive
- Hard disk
- VGA monitor (256 colors required for emulation)
- RS232 serial port
Operating System
- Compatible with Windows 3.1, Windows 95/98, Windows
NT and MacIntosh PowerPCs
Operating as the command console, the Site Manager
application controls your Edwards Message Centers anywhere
on your connected network. Group multiple Message Centers
into logical departments (sites) such as manufacturing,
customer service, lobby, etc. Send different messages to
each logical group or to any of your Message Centers. The
application allows you to:
- Create groups of Message Centers
- Transmit different messages to each group or
individually as required
- Configure your communications parameters
- Configure the type of message center (one line, two
line, etc.)
- Launch the message editor from the site manager
control panel
- Create and update counter files for automated count
down functions
- Schedule the time and date messages should be
displayed
The Message Editor lets you create custom messages to
be displayed on any Edwards Message Center.
- Create new messages with the integrated editor
- Embed any of the special commands in your message
- Access pre-programmed messages
- Create messages with custom graphics & special fonts
- Add function commands to your messages like Roll,
Scroll, Wipe, etc.
- Access the Message Emulator from the command menus
- Send a single message to a specific site or all
sites at once
The Message Emulator lets you preview your
messages on your computer screen before you send them to the
selected Message Center and eliminates the guesswork of
formatting your messages.
The Diagnostic Application quickly retrieves relevant
technical information about your Edwards Message Centers
anywhere on your connected network. In addition you can:
- Perform lamp tests
- Clear memory contents
- Change Message Center Addresses
- Query specific Message Centers
- Transmit information to specific Message Centers
- Broadcast test messages
The application allows you to:
Create groups of Message Centers
Transmit different messages to each group or
individually as required
Configure your communications parameters
Configure the type of message center (one line, two
line, etc.)
Launch the message editor from the site manager
control panel Create and update counter files for
automated count down functions Schedule the time and
date messages should be displayed
The Message Editor lets you create custom messages
to be displayed on any Edwards Message Center.
Create new messages with the integrated editor
Embed any of the special commands in your message
Access pre-programmed messages
Create messages with custom graphics & special fonts
Add function commands to your messages like Roll,
Scroll, Wipe, etc.
Access the Message Emulator from the command menus
Send a single message to a specific site or all
sites at once
The Message Emulator lets you preview your messages
on your computer screen before you send them to the
selected Message Center and eliminates the guesswork
of formatting your messages.
The Diagnostic Application quickly retrieves
relevant technical information about your Edwards
Message Centers anywhere on your connected network. In
addition you can:
Perform lamp tests
Clear memory contents
Change Message Center Addresses
Query specific Message Centers
Transmit information to specific Message Centers
Broadcast test messages |
|
Detailed Part Number Information: |
Part Number
Description |
Ratings |
|
|
Item Number |
MCN-2-0
Message Center Software |
|
|
MCPROTOCOL
Edwards Message Center Protocol |
|
|
|
|
LED Lighting sources are ideally
suited for applications where lighting requirements
are principally dictated by the need to be seen.
(Traffic signals, navigational beacons, obstruction
lighting, signage, runway
lighting, brake lights...)
Innovative traffic design and signaling,
designed as per your Specs. for their lighting needs. Amber alert, Futuristic i intersection
control, "Emergency Vehicle Approaching", signs have been designed and
delivered.
The sign you are reading is a 5 foot by 11 foot.
1.0 General Display
Characteristics
The unit shall display a legend in accordance with the
requirements in the federal Standard Highway Signs
Book. The message shall be bright in color against an
f l a t black background. The color of the illuminated
message is a function of the
Specified LED. The display shall consist of an array
of LEDs
Which f o r m the legend. The sign shall be
discernible attracting
Attention under any lighting conditions varying from t
o t an l
darkness
to bright s u n light. The message shall be clearly
legible
at a minimum of 300 ft (91 meters). When n o t
energized, the sign
Shall be blanked out (unreadable) with no phantom
images,
Regardless of solar intensity or direction. The sign
shall have a
Limited viewing a n g l e of 30' centered about the
optical axis and
Perpendicular to the surface of t h e matrix display.
The unit
Shall be capable of continuous operation over a
temperature range
Of -35'F to +130’F? (-37C to +74C) -
2.0 LED Module
The LEDs shall be mounted into one and one-half inch
pixels and
Arranged on t h e front aluminum faceplate to display
the requested
Message. The LED pixel unit shall be completely self
contained
and removable from the door.
3.0 Housing
The housing and door assembly shall be black powder
coated
Aluminum with an overall material thickness of 0.125
inches
(0.3cm). All seams shall be continuously welded, an
internal
Stiffening rib of 0.125 inch (0.3m) aluminum shall be
welded to
The housing f o r additional strength and rigidity.
Aluminum
Piano hinge and 8 latches will be provided to hold the
door shut.
A gasket will be used to seal the door of the housing.
All nuts,
Bolts, screws, washers, lock washers, and other
fastening
Materials shall be stainless steel.
4.0 Electrical Requirements
The normal failure of one LED shall not deactivate any
o t h e r LED.
Two power supplies shall operate the light sources.
The nominal
Input voltage shall be 120 volts AC. Connections for
primary
Wiring shall be made via a barrier terminal strip. All
wiring
Shall be #16 gauge wires.
5.0 Illumination System Requirements
The sign shall be illuminated by super bright LEDs.
Each LED
Shall be rated for 100,000 hours of continuous
operation with a
Luminous intensity of 1200 (typically) mcd at 20ma. In
a standard
LED sign, the LEDs shall have the following
characteristics:
Size T-1 3/4
Peak Wave Length 630 nm
Brightness 1400 (typically) mcd
6.0 Optional Dimmer
There shall be available, as an option, a photocell
and dimming
Circuit, shielded from any direct light source, which
are capable
Of automatically adjusting the message light output in
response
To changes in ambient light conditions. The
photoelectric cell
Shall operate automatically to brighten the intensity
of the sign
Illumination to one-half of t h e daylight
illumination as
Nighttime occurs. Pixels shall be wired t o utilize h
a l f the U D s
In dim mode during one 24 hour cycle and alternately
the second
Half of the pixel in the second 24 hour cycle to
evenly balance
The use of all LEDs.
7. 0 Dimensions
Units designed for traffic control applications are
dimensioned
In accordance with the Manual on Uniform Traffic
Control Devices.
i.e. 24 inch (6lcm) x 24 inch, 24 inch x 30 inch
(76cm), 30 inch
x 30 inch, etc. Units designed for other applications
can be
Specially dimensioned at extra cost. All housings are
6 inches
Deep.
8.0 Warranty
OkSolar.com*s LED Blackout signs are warranted against
defects
In materials and workmanship for a period of three (3)
years from
Original shipment date.
Manufacturer and
Distributor of, Amber Alert, Innovative traffic design
and signaling, Traffic signals, navigational beacons,
obstruction lighting, signage, runway lighting, brake
lights, Emergency Vehicle Approaching, signs have been
designed and delivered.,
|