Visual Signals
Flashing,
Steady-On, Strobe and Stackable Status Indicators
Communicating. Alerting. Warning!
Whatever your need for a visual signal, Edwards is the one-source solution with
the industry's broadest line of visual signals. AdaptaLight ® and Triliptical ®
Stackable Beacons combine audible & visual signaling and stack five modules high
in any combination of strobe, flashing, steady-on with LED or incandescent
modules.
Edwards rotating, flashing, or strobe AdaptaBeacon ® lights are available with
either halogen, incandescent, or LED light sources. Select from a choice of
outdoor, indoor, and Division 1 and 2 models. Six lens colors are available. A
signal for every signal need. From cranes and conveyors to safety and security,
signals that can be both seen and heard.,
105SLEDR-N5,105SLEDA-N5, 105FLEDR-N5, 105FLEDA-N5, 105SINHR-G1,105SINHA-G1,
105SINHR-N5, 105SINHA-N5, 105FINHR-G1, 105FINHA-G1, 105FINHR-N5, 105FINHA-N5,
105STR-G1, 105STA-G1, 105STR-N5, 105STA-N5, 105HISTR-N5, 105HISTA-N5
105 Series
AdaptaBeacon
Adverse Location Signal
Type 4X, Marine Rated,
Div. 2, UL 1971 Listed Model

Features
- Corrosion resistant
- Six available light sources:
- Steady-on incandescent
- Steady-on LED cluster
- Flashing incandescent
- Flashing LED cluster
- 300,000 peak candlepower
- 800,000 peak candlepower, 8 joule high intensity strobe
- Three mounting bases:
- 3/4" (19 mm) pipe mount attachment
- Outlet box attachment
- Wall mounting bracket
Agency Approvals:
Application/Installation:
The Edwards 105 Series are
heavy duty beacons designed for use in industrial applications where a
corrosion resistant Type 4X enclosure is required. The housing is
manufactured from glass-reinforced thermoplastic polyester resin and
incorporates brass hardware. The double fresnel lens is made of
polycarbonate.
All light sources are supplied as UL listed component assemblies – ready
to be attached to the selected mounting base.
The Edwards 105DHISTC-FJ high intensity strobe is designed for use in
compatible fire alarm system and other applications requiring electrical
supervision of signaling circuit field wiring.
All units can be mounted on 3/4" (19mm) NPT conduit using the 105PM
attachment. The units can also be surface or wall mounted using the 105BX
and 105BM attachments respectively. For indoor applications, may be
vertically mounted with lenses facing up or down. For weatherproof
installation, it is recommended that the unit be mounted with the lens
facing up or with the lens horizontal.
|
Beacons Flashing Lights
Feature NEMA 4X and marine-rated
enclosure when asembled in accordance with installation instructions.
Mounting options include pipe mount, outlet box and mounting bracket.
Steady-On and Flashing models are available with either a high intensity
halogen bulb or a long life LED. Strobes are available with 300,000 peak
candela or high intensity 800,000 peak candela output. Order light module
and mounting base separately. UL listed for use in Class 1, Division 2,
Groups A, B, C, and D, Class 2, Division 2, Groups F and G and Class 3
Hazardous Locations, CSA certified, CE marked.
LIGHT MODULES ADVERSE
LOCATION BEACON LIGHTS
|
| |
|
|
 |
 |
 |
| |
|
Detailed Part Number Information: |
Part
Number
Description |
Ratings |
|
|
Item
Number |
105DHISTC-FJ
Adverse Location Beacon - Fire Alarm Listed |
UL
1971 Listed
20-30V DC, 1.08 - 0.83A
24.9VA |
Clear
26CD |
105FINHA-G1
Flashing Halogen Light Module |
24
VDC, 0.8 A |
Amber |
105FINHA-G5
Flashing Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Amber |
105FINHA-N5
Flashing Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Amber |
105FINHB-G1
Flashing Halogen Light Module |
24
VDC, 0.8 A |
Blue
|
105FINHB-G5
Flashing Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Blue
|
105FINHB-N5
Flashing Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Blue
|
105FINHC-G1
Flashing Halogen Light Module |
24
VDC, 0.8 A |
Clear |
105FINHC-G5
Flashing Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Clear |
105FINHC-N5
Flashing Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Clear |
105FINHG-G1
Flashing Halogen Light Module |
24
VDC, 0.8 A |
Green |
105FINHG-G5
Flashing Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Green |
105FINHG-N5
Flashing Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Green |
105FINHM-G1
Flashing Halogen Light Module |
24
VDC, 0.8 A |
Magenta |
105FINHM-G5
Flashing Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Magenta |
105FINHM-N5
Flashing Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Magenta |
105FINHR-G1
Flashing Halogen Light Module |
24
VDC, 0.8 A |
Red
|
105FINHR-G5
Flashing Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Red
|
105FINHR-N5
Flashing Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Red
|
105FLEDA-G1
Flashing LED Light Module |
24
VDC, 0.062 A |
Amber |
105FLEDA-N5
Flashing LED Light Module |
120
VAC 50/60 Hz, 0.022 |
Amber |
105FLEDB-G1
Flashing LED Light Module |
24
VDC, 0.062 A |
Blue
|
105FLEDB-N5
Flashing LED Light Module |
120
VAC 50/60 Hz, 0.022 |
Blue
|
105FLEDG-G1
Flashing LED Light Module |
24
VDC, 0.062 A |
Green |
105FLEDG-N5
Flashing LED Light Module |
120
VAC 50/60 Hz, 0.022 |
Green |
105FLEDR-G1
Flashing LED Light Module |
24
VDC, 0.062 A |
Red
|
105FLEDR-N5
Flashing LED Light Module |
120
VAC 50/60 Hz, 0.022 |
Red
|
105HISTA-N5
8 Joule High Intensity Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Amber
800,000CD |
105HISTA-R5
8 Joule High Intensity Strobe Module |
240
VAC 50/60 Hz, 0.05 A |
Amber
800,000CD |
105HISTB-N5
8 Joule High Intensity Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Blue
800,000CD |
105HISTB-R5
8 Joule High Intensity Strobe Module |
240
VAC 50/60 Hz, 0.05 A |
Blue
800,000CD |
105HISTC-N5
8 Joule High Intensity Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Clear
800,000CD |
105HISTC-R5
8 Joule High Intensity Strobe Module |
240
VAC 50/60 Hz, 0.05 A |
Clear
800,000CD |
105HISTG-N5
8 Joule High Intensity Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Green
800,000CD |
105HISTG-R5
8 Joule High Intensity Strobe Module |
240
VAC 50/60 Hz, 0.05 A |
Green
800,000CD |
105HISTM-N5
8 Joule High Intensity Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Magenta
800,000CD |
105HISTM-R5
8 Joule High Intensity Strobe Module |
240
VAC 50/60 Hz, 0.05 A |
Magenta
800,000CD |
105HISTR-N5
8 Joule High Intensity Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Red
800,000CD |
105HISTR-R5
8 Joule High Intensity Strobe Module |
240
VAC 50/60 Hz, 0.05 A |
Red
800,000CD |
105SINHA-G1
Steady-On Halogen Light Module |
24
VDC, 0.8 A |
Amber |
105SINHA-G5
Steady-On Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Amber |
105SINHA-N5
Steady-On Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Amber |
105SINHB-G1
Steady-On Halogen Light Module |
24
VDC, 0.8 A |
Blue
|
105SINHB-G5
Steady-On Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Blue
|
105SINHB-N5
Steady-On Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Blue
|
105SINHC-G1
Steady-On Halogen Light Module |
24
VDC, 0.8 A |
Clear |
105SINHC-G5
Steady-On Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Clear |
105SINHC-N5
Steady-On Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Clear |
105SINHG-G1
Steady-On Halogen Light Module |
24
VDC, 0.8 A |
Green |
105SINHG-G5
Steady-On Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Green |
105SINHG-N5
Steady-On Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Green |
105SINHM-G1
Steady-On Halogen Light Module |
24
VDC, 0.8 A |
Magenta |
105SINHM-G5
Steady-On Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Magenta |
105SINHM-N5
Steady-On Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Magenta |
105SINHR-G1
Steady-On Halogen Light Module |
24
VDC, 0.8 A |
Red
|
105SINHR-G5
Steady-On Halogen Light Module |
24
VAC 50/60 Hz, 0.8 A |
Red
|
105SINHR-N5
Steady-On Halogen Light Module |
120
VAC 50/60 Hz, 0.2 A |
Red
|
105SLEDA-G1
Steady-On LED Light Module |
24
VDC, 0.062 A |
Amber |
105SLEDA-N5
Steady-On LED Light Module |
120
VAC 50/60 Hz, 0.062 A |
Green |
105SLEDB-G1
Steady-On LED Light Module |
24
VDC, 0.062 A |
Blue
|
105SLEDB-N5
Steady-On LED Light Module |
120
VAC 50/60 Hz, 0.022 |
Blue
|
105SLEDG-G1
Steady-On LED Light Module |
24
VDC, 0.062 A |
Green |
105SLEDG-N5
Steady-On LED Light Module |
120
VAC 50/60 Hz, 0.062 A |
Red
|
105SLEDR-G1
Steady-On LED Light Module |
24
VDC, 0.062 A |
Amber |
105SLEDR-N5
Steady-On LED Light Module |
120
VAC 50/60 Hz, 0.022 |
Red
|
105STA-G1
3 Joule Strobe Module |
24
VDC, 0.3 A |
Amber
300,000CD |
105STA-N5
3 Joule Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Amber
300,000CD |
105STA-R5
3 Joule Strobe Module |
240
VAC 50/60 Hz, 0.02 A |
Amber
300,000CD |
105STB-G1
3 Joule Strobe Module |
24
VDC, 0.3 A |
Blue
300,000CD |
105STB-N5
3 Joule Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Blue
300,000CD |
105STB-R5
3 Joule Strobe Module |
240
VAC 50/60 Hz, 0.02 A |
Blue
300,000CD |
105STC-G1
3 Joule Strobe Module |
24
VDC, 0.3 A |
Clear
300,000CD |
105STC-N5
3 Joule Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Clear
300,000CD |
105STC-R5
3 Joule Strobe Module |
240
VAC 50/60 Hz, 0.02 A |
Clear
300,000CD |
105STG-G1
3 Joule Strobe Module |
24
VDC, 0.3 A |
Green
300,000CD |
105STG-N5
3 Joule Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Green
300,000CD |
105STG-R5
3 Joule Strobe Module |
240
VAC 50/60 Hz, 0.02 A |
Green
300,000CD |
105STM-G1
3 Joule Strobe Module |
24
VDC, 0.3 A |
Magenta
300,000CD |
105STM-N5
3 Joule Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Magenta
300,000CD |
105STM-R5
3 Joule Strobe Module |
240
VAC 50/60 Hz, 0.02 A |
Magenta
300,000CD |
105STR-G1
3 Joule Strobe Module |
24
VDC, 0.3 A |
Red
300,000CD |
105STR-N5
3 Joule Strobe Module |
120
VAC 50/60 Hz, 0.1 A |
Red
300,000CD |
105STR-R5
3 Joule Strobe Module |
240
VAC 50/60 Hz, 0.02 A |
Red
300,000CD |
|
Accessories |
105BM
Wall Mounting Bracket |
|
|
105BX
Outlet Box Attachment |
|
|
105PM
Pipe Mount Attachment |
|
|
|
Replacement Parts |
105H-LA
Replacement Lens |
|
Amber |
105H-LB
Replacement Lens |
|
Blue
|
105H-LC
Replacement Lens |
|
Clear |
105H-LG
Replacement Lens |
|
Green |
105H-LM
Replacement Lens |
|
Magenta |
105H-LR
Replacement Lens |
|
Red
|
105-LA
Replacement Lens |
|
Amber |
105-LB
Replacement Lens |
|
Blue
|
105-LC
Replacement Lens |
|
Clear |
105-LG
Replacement Lens |
|
Green |
105-LM
Replacement Lens |
|
Magenta |
105-LR
Replacement Lens |
|
Red
|
50LMP-20WH
20 Watt Halogen Bulb |
|
|
50LMP-25WH
25 Watt Halogen Bulb |
|
|
91B-ST
Replacement Strobe Tube |
|
|
92-ST
Replacement Strobe Tube |
|
|
|
Marine Marking
- Small safety/hazard buoys
- Recreational sporting and boating shore infrastructure
- Perimeter marking for fish and aquaculture farming facilities
- Marina walkways and dock ends
- Boat houses
- Private Docks
- Channels and canals
- Waterfront safety lighting
- Rock outcroppings near private docks
- Coastal signs (i.e. "Slow Down, Children Swimming")
- Swimming rafts (permanent and temporary)
- Floats for crab, shrimp, and prawn traps, etc.
- Cod and halibut Introduction lines
- Floats on oil spill barriers
- Floats for dredging lines
Railway Marking
- Blue 501 lights are used extensively to meet FRA regulations for hazard
marking on rail tracks
Other Marking Applications
- Emergency phone booths on university campuses
- Emergency phone booths along roadsides
- Barns on farms
- Temporary Hunting Camps
- Park and campground washrooms
- Bus stops
Applications:
|