|
|
|
Access Control for Building and Gated Community security,
complete line of controllers, radio receivers, transmitters, accessories for
configuring and upgrading access control systems. Capabilities include telephone
entry systems, radio-based products for remote, keyless entry, panic alarms and
greater handicapped access, keypads, swipe card readers, booms and other
commercial applications

EDI provides traffic
control and access professionals with
reliable hi-tech component products
(signal monitors, vehicle detectors,
power supplies, load switches, flashers,
bus interface units, and detector
harnesses) that offer value added
benefits for traffic signal cabinets as
well as gate, parking, and/or door
operators. These benefits include
built-in set-up and diagnostic tools
which literally save technicians time
and money to accurately install and
trouble-shoot these mission critical
systems, thus banking budgeted dollars
and maximizing profits.
LMD DEFLECTOMETER Series
Vehicle Detectors for Traffic
To help
users install and maintain traffic
control loop systems quickly and
reliably, EDI introduces the LMD
DEFLECTOMETER series vehicle detectors
DC Isolator
The Model 242 meets and exceeds all
Caltrans requirements. The Model 242E
adds enhanced trouble shooting and
signal filtering features
Advanced LCD Vehicle Detectors
The ORACLE E series provide numerous
tools, meters, data, and diagnostics to
bring you the most ENHANCED full
featured vehicle detectors on the market
today.
DEFLECTOMETER™ Vehicle Detectors
for Access Control
To help users install and maintain
access control operator systems quickly
and reliably, EDI introduces the
LMA-1400 DEFLECTOMETER™ series vehicle
detectors.
MMU-16LE SmartMonitor™
Introducing the MMU-16LE, a menu driven
LCD based TS-2 MMU. Whether you’re a
NOVICE or EXPERT Signal Technician.
Vehicle Detectors for Access
Control.
To allow your gate, parking, and
roll-up door operator systems to operate
reliably and trouble free, EDI has
released the simple to use LMA-100 and
LMA-200 series vehicle detectors
Cabinet Power Supply
Introducing the PS-250, a heavy duty
power supply for cabinets where high
current video detection devices are
used. The PS-250 provides 5 Amps at 12
Vdc over the full Nema temperature
range.
|
|
|
Traffic > Signal
Monitors
NEMA TS-2 Signal Monitors
MMU-16LE SmartMonitor™ LCD Series
The MMU-16LE series Malfunction
Management Unit (MMU) exceeds all the
requirements set forth in the NEMA
Standard TS2-2003, Part 4. The model
MMU-16LE includes two large area Liquid
Crystal Displays (LCD) for a continuous
Full Intersection display. A separate
graphical LCD provides a menu driven
interface to status, signal voltages,
configuration, event logs, and the
integrated context sensitive Help
System. The built-in Setup Wizard
ensures that the enhanced monitor
programming is done quickly and
accurately, even by a novice. The
industry first Diagnostic Wizard
automatically pinpoints malfunctioning
signals and offers trouble shooting
advice. An EIA232 port is used to
communicate with a Personal Computer
using field proven EDI ECcom™ software.
Monitor status, event logs, and Signal
Sequence History logs are stored in
nonvolatile memory for diagnostic and
archival purposes.
MMU-16LE 12/16 channel MMU-16E Series
The MMU-16E series Malfunction
Management Units (MMU) exceed all the
requirements set forth in the NEMA
Standard TS2-2003 , Part 4 (TS2-1992 has
been revised!). These units are intended
to provide basic conflict and voltage
monitoring for NEMA TS-2 traffic
controller assemblies while maintaining
downward compatibility with NEMA TS-1
assemblies. The model MMU-16E includes a
RYG Full Intersection display along with
an RS232 port which is used to
communicate with a Personal Computer
using EDI ECcom™ software. Monitor
status, event logs, and Signal Sequence
History logs are stored in nonvolatile
memory for diagnostic and archival
purposes. MMU-16E 12/16 channel
NEMA TS-1 Signal Monitors
SSM-LE Series
The SSM-LE series Signal Monitors exceed
all the requirements set forth in the
NEMA Standard TS-1-1994, Part 6. These
units are intended to provide enhanced
conflict and voltage monitoring for
traffic controller assemblies with
additional capabilities for broader
fault coverage and diagnostic
troubleshooting. The SSM-6LE and
SSM-12LE units include a Full
Intersection Liquid Crystal display
(LCD) along with an RS232 port which is
used to communicate with a Personal
Computer using EDI ECcom™ software.
Monitor status, event logs, and Signal
Sequence History logs are stored in
nonvolatile memory for diagnostic and
archival purposes. SSM-6LE 6 channel
SSM-12LE 12 channel
SSM-18LEPR 18 channel (not ECcom™
compatible)
SSM-E Series
The SSM-E series Signal Monitors exceed
all the requirements set forth in the
NEMA Standard TS-1-1994, Part 6. These
units are intended to provide enhanced
conflict and voltage monitoring for
traffic controller assemblies with
additional capabilities for broader
fault coverage.
SSM-3E 3 channel
SSM-6E 6 channel
SSM-12E 12 channel
NSM Series
The NSM series Signal Monitors exceed
all the requirements set forth in the
NEMA Standard TS-1-1994, Part 6. These
units are intended to provide basic
conflict and voltage monitoring for
traffic controller assemblies.
NSM-3 3 channel
NSM-6 6 channel
NSM-12 12 channel
Type 170/179/2070 Signal Monitors
2010 Series Signal Monitors
2010ECL Series
The model 2010ECL is a 210ECL monitor
configured for operation with a 2070
Controller Unit. It provides all the
features of the 210ECL model as well as
minimum flash capabilities for 2070 boot
capability. The 2010ECL series monitor
is compatible with 170, 179 and 2070
Controller Units. It is a recommended
replacement for the 210E and 210ECL
monitor in new installations using 170
or 2070 Controller Units.
2010 Series
The model 2010 is a 210E monitor
configured for operation with a 2070
Controller Unit. It provides all the
features of the 210E model as well as
minimum flash capabilities for 2070 boot
capability. The 2010 series monitor is
compatible with 170, 179 and 2070
Controller Units. It is a recommended
replacement for the 210E monitor in new
installations using 170 or 2070
Controller Units.
210 Series Signal Monitors
210ECL Series
The model 210ECL includes the functions
of the 210E unit and adds a RYG Full
Intersection display along with an RS232
port which is used to communicate with
the Controller Unit operational software
or a Personal Computer using EDI ECcom™
software. Monitor status, event logs,
and Signal Sequence History logs are
stored in nonvolatile memory for
diagnostic and archival purposes.
210ECL
210E Series
The model 210E meets all the
requirements set forth in the Caltrans
Traffic Signal Control Specifications
and provides the enhanced functions of
Red signal monitoring, Dual Indication
monitoring and Clearance monitoring.
210E
210N Series
The model 210N meets all the
requirements set forth in the Caltrans
Traffic Signal Control Specifications
with the addition of Red signal
monitoring.
210N
210C Series
The model 210C meets all the
requirements set forth in the Caltrans
Traffic Signal Control Specifications.
These units are intended to provide
basic conflict and voltage monitoring
for Type 170/179 traffic controller
assemblies. 210C Caltrans QPL listed
210-NY NYSDOT QPL listed
ITS Cabinet Signal Monitors
CMU-212 Series
The EDI CMU-212 Cabinet Monitor Unit is
intended to operate with the AMU-214
Auxiliary Monitor Unit to form a compact
and modular cabinet malfunction
management system for the ITS Cabinet.
The CMU-212 functions as the main
cabinet fault monitoring component. It
offers the broadest fault coverage of
any monitoring system and incorporates
full event logging and status reporting,
providing the signal technician with
powerful monitoring and trouble-shooting
tools to ensure that cabinet
malfunctions are detected, diagnosed,
and repaired with confidence.
The CMU-212 meets all requirements of
the ASHTO/ITE/NEMA Intelligent
Transportation System (ITS) Standard
Specification for Roadside Cabinets
Version 01.02.15, as well as the
Caltrans TEES, August 2002 requirements.
CMU-212 32 channel Monitor Unit
AMU-214 Series
The EDI AMU-214 Auxiliary Monitor
Unit is intended to operate with the
CMU-212 Cabinet Monitor Unit to form a
compact and modular cabinet malfunction
management system for the ITS Cabinet.
The AMU-214 provides the voltage and
current data acquisition function of the
cabinet monitoring system. Up to four
AMU-214 units can be installed in ten
different cabinet configurations with
each CMU-212.
The AMU-214 meets all requirements of
the ASHTO/ITE/NEMA Intelligent
Transportation System (ITS) Standard
Specification for Roadside Cabinets
Version 01.02.15, as well as the
Caltrans TEES, August 2002 requirements.
AMU-214 Dual mode 6 channel and 14
channel
MonitorKey™ Programming Tool
The EDI MonitorKey™ CMU Data Key
Programming Tool provides the
programming interface between a Personal
Computer and the Data Key used to store
configuration parameters in the CMU-212.
The compact tool connects to a serial
port of the PC and uses the MonitorKey™
Windows based software to read, write,
and verify the contents of the Data Key.
Software Wizards are provided to
simplify the initial setup of the
parameter database and check for
consistency errors. MonitorKey™
Programming Tool and included software
Products > Traffic >
Inductive Loop Detectors
NEMA TS 2 TYPE - Vehicle /
Intersection Detectors - Rack Mount
LM 622 Series: Two channel rack mount
NEMA TS2 detector with 15 levels of
sensitivity, four loop frequencies,
three modes of operation. Timing is an
option.
LM 624 Series: Four channel rack mount
NEMA TS-2 detector with 15 levels of
sensitivity, four loop frequencies,
three modes of operation. Timing is
optional.
LM 642t Series: Two channel rack mount
NEMA TS2 detector with 15 levels of
sensitivity, four loop frequencies,
three modes of operation, timing, and
System / Count outputs.
NEMA TS 1 Type - Vehicle /
Intersection Detectors - Rack Mount
Oracle 2E Series: Two channel
rack mount detector with LCD Display, 20
levels of sensitivity, eight loop
frequencies, three modes of operation.
Oracle 4E Series: Four channel
rack mount detector with LCD Display, 20
levels of sensitivity, eight loop
frequencies, three modes of operation.
LM 602 Series: Two channel rack
mount detector with 15 levels of
sensitivity, four loop frequencies,
three modes of operation. Timing and
relay outputs are options.
LM 612 Series: Two channel rack
mount thumbwheel detector with 15 levels
of sensitivity, three loop frequencies,
three modes of operation. Timing and
relay outputs are options.
LM 604 Series: Four channel rack
mount detector with 15 levels of
sensitivity, four loop frequencies,
three modes of operation. Timing is
optional.
LM 602-ST: The LM 602-ST "Speed
Trap" or "Traffic Calming" detector is
designed to use two loops to measure
vehicle speed. If the measured speed
exceeds a switch selectable threshold, a
pulse output is generated on the Channel
1 output. Applications include traffic
calming and advanced warning
indications. This two channel rack mount
detector has 15 levels of sensitivity
and four loop frequencies.
LM 632t Series: Two channel rack
mount detector with 15 levels of
sensitivity, four loop frequencies,
three modes of operation, timing and
System / Count outputs. Relay outputs
are an option.
NEMA TS 1 Type - Vehicle /
Intersection Detectors - Shelf Mount
Oracle /S1 Series: Single channel
shelf mount detector with LCD Display,
15 levels of sensitivity, eight loop
frequencies, three modes of operation.
Oracle /S2 Series: Dual channel
shelf mount detector with LCD Display,
15 levels of sensitivity, eight loop
frequencies, three modes of operation.
LM 301 Series: Single channel
shelf mount detectors with 16 levels of
sensitivity, four loop frequencies, and
three modes of operation. Timing and
solid state outputs are options.
LM 331 Series: Single channel
shelf mount detectors with 16 levels of
sensitivity, four loop frequencies,
three modes of operation, timing and
separate System / Count output. Solid
state outputs are options.
LM 302 Series: Two channel shelf
mount detectors with 15 levels of
sensitivity, four loop frequencies, and
three modes of operation. Timing and
solid state outputs are options.
LM 332 Series: Two channel shelf
mount detectors with 15 levels of
sensitivity, four loop frequencies,
three modes of operation, timing and
separate System / Count outputs. Solid
state outputs are optional.
LM 304 Series: Four channel shelf
mount detectors with 15 levels of
sensitivity, four loop frequencies, and
three modes of operation. Solid state
outputs are optional.
Mating Harness for single and dual
channel shelf mount vehicle detectors is
LMH8
CALTRANS 170/2070 TYPE - Vehicle /
Intersection Detectors - Rack Mount
LM 222 Series: Two channel rack mount
detector with 8 levels of sensitivity,
four loop frequencies, three modes of
operations. Caltrans QPL.
SYSTEM / COUNT TYPE - Vehicle /
Intersection Detectors - Shelf Mount –
NEMA TS 1
Oracle /S1 Series: Single channel
shelf mount detector with LCD Display,
15 levels of sensitivity, eight loop
frequencies, three modes of operation.
Oracle /S2 Series: Dual channel
shelf mount detector with LCD Display,
15 levels of sensitivity, eight loop
frequencies, three modes of operation.
LM 331 Series: Single channel
shelf mount detectors with 16 levels of
sensitivity, four loop frequencies,
three modes of operation, timing and
separate System / Count output. Solid
state outputs are options.
LM 332 Series: Two channel shelf
mount detectors with 15 levels of
sensitivity, four loop frequencies,
three modes of operation, Timing and
separate System / Count outputs. Solid
state outputs are optional.
Mating Harness for single and dual
channel shelf mount vehicle detectors is
LMH8.
SYSTEM / COUNT TYPE - Vehicle /
Intersection Detectors - Rack Mount –
NEMA TS 1
Oracle 2EC Series: Two channel
rack mount detector with LCD Display, 20
levels of sensitivity, eight loop
frequencies, three modes of operation.
Oracle 4EC Series: Four channel
rack mount detector with LCD Display, 20
levels of sensitivity, eight loop
frequencies, three modes of operation.
LM 632t Series: Two channel rack
mount detector with 15 levels of
sensitivity, four loop frequencies,
three modes of operation, timing, and
System / Count outputs. Relay outputs
are an option.
SYSTEM / COUNT TYPE - Vehicle /
Intersection Detectors - Rack Mount –
NEMA TS 2
Oracle 2EC Series: Two channel
rack mount detector with LCD Display, 20
levels of sensitivity, eight loop
frequencies, three modes of operation.
Oracle 4EC Series: Four channel
rack mount detector with LCD Display, 20
levels of sensitivity, eight loop
frequencies, three modes of operation.
LM 642t Series: Two channel rack
mount NEMA TS2 detector with 15 levels
of sensitivity, four loop frequencies,
three modes of operation, timing, and
System / Count outputs.
SYSTEM / COUNT TYPE - Vehicle /
Intersection Detectors - Rack Mount –
CALTRANS 170/2070 Type
Oracle 2EC Series: Two channel
rack mount detector with LCD Display, 20
levels of sensitivity, eight loop
frequencies, three modes of operation
|
Products > Traffic > Load Switches &
Flashers
The solid aluminum extruded heat sink
design of the EDI Load Switch and
Flasher ensures lower operating
temperatures for reliable long term
operation.
AC Line Solid State Load Switches
Model 510: The model 510 solid
state Load Switch meets all requirements
of NEMA TS-1 and NEMA TS-2 Standards.
Maximum load current is 10 Amps RMS over
full operation temperature.
Model 510-225: The model 510-225
solid state Load Switch meets all
requirements of NEMA TS-1 and NEMA TS-2
Standards. Maximum load current is 10
Amps RMS over full operation
temperature. This unit operates at 220
Volts and 50 Hertz.
EDI Model 510 Full Load Test Report
Model 200: The model 200 solid
state Switch Pack is compatible with
Type 170 cabinets. Maximum load current
is 10 Amps RMS over full operation
temperature.
Model 200-225: The model 200-225
solid state Switch Pack is compatible
with Type 170 cabinets. Maximum load
current is 10 Amps RMS over full
operation temperature. This unit
operates at 220 Volts and 50 Hertz.
AC Line Solid State Flashers
Model 810: The model 810 solid
state Flasher meets all requirements of
NEMA TS-1 and NEMA TS-2 Standards.
Maximum load current is 15 Amps RMS per
circuit over full operation temperature.
Model 810-225: The model 810-225
solid state Flasher meets all
requirements of NEMA TS-1 and NEMA TS-2
Standards. Maximum load current is 15
Amps RMS per circuit over full operation
temperature. This unit operates at 220
Volts and 50 Hertz.
Model 204: The model 204 solid
state Flasher is compatible with Type
170 cabinets. Maximum load current is 15
Amps RMS per circuit over full operation
temperature.
Model 204-225: The model 204-225
solid state Flasher is compatible with
Type 170 cabinets. Maximum load current
is 15 Amps RMS per circuit over full
operation temperature. This unit
operates at 220 Volts and 50 Hertz.
DC Solid State Load Switches
Model 548: The model 548 solid
state load switch is intended for DC
powered applications. Maximum load
current is 10 Amps at 48 Vdc. Each
output is over-current and short circuit
protected for maximum reliability. This
unit is physically compatible with the
standard NEMA or Type 170 load switch.
DC Solid State Flashers
Model 848: The model 848 solid
state Flasher is intended for DC powered
applications. Maximum load current is 15
Amps at 48 Vdc per circuit. Each output
is over-current and short circuit
protected for maximum reliability. This
unit is physically compatible with the
standard NEMA or Type 170 flasher
|
Products > Traffic > Auxiliary
Devices
NEMA TS-2 Bus Interface Unit (BIU)
Model 700: The model BIU-700 Bus
Interface Unit (BIU) performs the
interface between Port 1 of the
Controller Unit and the Loop Detector
Racks, Terminals and Facilities, and
other devices in a NEMA TS-2 Cabinet
Assembly. Its functions include
controlling load switch outputs,
detector resets, communicating with
Inductive Loop Detectors and other
devices, and the conditioning and
conversion of Terminals and Facilities
and Loop Detector call inputs for the
Controller Unit.
Model 720: The model BIU-720 Bus
Interface Unit (BIU) adds an additional
port for communicating with rack devices
meeting the NEMA TS2-2003 BIU2
requirements.
Model 730: The model BIU-730 Bus
Interface Unit (BIU) adds an additional
port for communicating with rack devices
meeting the NEMA TS2-2003 BIU2
requirements but electrically compliant
with EIA-232 electrical standards.
Model 740: The model BIU-740 Bus
Interface Unit (BIU) provides an EIA-232
port on the front panel for custom
applications.
NEMA TS-2 Cabinet Power Supply
NEMA TS-2 Cabinet Power Supplies
PS-200: The model PS-200 power
supply meets or exceeds all requirements
for NEMA TS2-2003. It provides +24 VDC
at 2 Amps, +12 VDC at 2 Amps, 12 VAC at
0.25 Amps, and a Line Frequency
reference output. LED indicators and
fuses are provided for all three output
voltages.
PS-250: The model PS-250 power
supply meets or exceeds all requirements
for NEMA TS2-2003. It provides +24 VDC
at 2 Amps, +12 VDC at 5 Amps, 12 VAC at
0.25 Amps, and a Line Frequency
reference output. LED indicators and
fuses are provided for all three output
voltages.
ITS Cabinet Serial Interface Unit
(SIU)
SIU-218: The model SIU-218 Serial
Interface Unit (SIU) performs the
interface between Serial Bus #1 of the
Advanced Controller Unit (ATC) and the
Input Assembly, Output Assembly, and
other devices in an ITS Cabinet. Its
functions include controlling load
switch outputs, detector resets,
communicating with inductive loop
detectors and other devices, and the
conditioning and conversion of loop
detector call inputs for the ATC. The
SIU-218 Serial Interface Unit meets all
requirements of the ASHTO/ITE/NEMA
Intelligent Transportation System (ITS)
Standard Specification for Roadside
Cabinets Version 01.02.15, as well as
the Caltrans TEES, August 2002
requirements.
|
Products > Traffic > Software
ECcom™
ECcom™ PC software runs on a Windows
based personal computer and gives a
signal technician the capability to
retrieve, display, store, and print
real-time status and historical data
from the EDI MMU-16LE, MMU-16E, SSM-LE,
2010ECL, 210ECL, and ITS CMU series
monitors.
MonitorKey™
Coming Soon.
|
|
Products > Traffic >
Power Supplies
Detector Power Supplies - Rack Mount
PS-150: The PS-150 four channel
power supply is built on international
format cards with gold edge connector
fingers. Each power supply channel will
nominally supply 24Vdc at 0.25 Amp when
connected to the 115 VAC line. Output
current is rated to 0.5 Amp per output
over temperature.
PS-100: The PS-100 four channel
power supply is built on international
format cards with gold edge connector
fingers. Each power supply channel will
supply 24Vdc at 0.25 Amp (1.0 Amp total)
when connected to the 115 VAC line.
PS-050: The PS-050 two channel
power supply is built on international
format cards with gold edge connector
fingers. Each power supply channel will
supply 24Vdc at 0.25 Amp (0.5 Amp total)
when connected to the 115 VAC line.
Cabinet Power Supplies - Shelf Mount
PS-200: The model PS-200 power
supply meets or exceeds all requirements
for NEMA TS2-2003. It provides +24 VDC
at 2 Amps, +12 VDC at 2 Amps, 12 VAC at
0.25 Amps, and a Line Frequency
reference output. LED indicators and
fuses are provided for all three output
voltages.
PS-250: The model PS-250 power
supply meets or exceeds all requirements
for NEMA TS2-2003. It provides +24 VDC
at 2 Amps, +12 VDC at 5 Amps, 12 VAC at
0.25 Amps, and a Line Frequency
reference output. LED indicators and
fuses are provided for all three output
voltages. |
Products > Access > Inductive Loop
Detectors
Parking and Access Control - Vehicle
Detectors - 11 pin Amphenol Connector -
Box Type
Note: The LMA-1100 and LMA-1200
DEFLECTOMETER™ Series detectors have
been upgraded to the LMA-1150 and
LMA-1250 series.
LMA 1150: Single channel with
programmable single relay output. The
DEFLECTOMETER™ display helps optimize
the proper sensitivity setting to detect
all vehicles including motorcycles. NO
MORE GUESS WORK WHEN SETTING
SENSITIVITY! The LMA-1150 Series offer
two models to handle any input power
requirement:
LMA-1150-LV (12Vdc, 24Vdc, & 24Vac)
LMA-1150-HV (120Vac to 240Vac)
Note: The LMA-1150 Series is offered in
either Fail Safe or Fail Secure
configurations.
LMA 1250: Single channel with
programmable dual relay output. The
DEFLECTOMETER™ display helps optimize
the proper sensitivity setting to detect
all vehicles including motorcycles. NO
MORE GUESS WORK WHEN SETTING
SENSITIVITY! The LMA-1250 Series offer
two models to handle any input power
requirement:
LMA-1250-LV (12Vdc, 24Vdc, & 24Vac)
LMA-1250-LP (12Vdc, 24Vdc) Low Power
LMA-1250-HV (120Vac to 240Vac)
Note: The LMA-1250 Series is offered in
either Fail Safe or Fail Secure
configurations.
LMA-100: Single channel with
single relay output. The LMA-100 Series
offer two models to handle any input
requirement:
LMA-100-LV (12VDC, 24VDC, & 24VAC)
LMA-100-HV (120VAC to 240VAC)
Note: The LMA-100 Series is offered in
either Fail Safe or Fail Secure
configurations.
LMA-200: Single channel with
programmable dual relay output. The
LMA-200 Series offer two models to
handle any input requirement:
LMA-200-LV (12VDC, 24VDC, & 24VAC)
LMA-200-HV (120VAC to 240VAC)
Note: The LMA-200 Series is offered Fail
Safe configuration only.
Mating Harness for models LMA-1150,
LMA-1250, LMA-100, and LMA-200 series is
model LMH4-11.
Parking and Access Control – Vehicle
Detectors - 10 pin Molex Connector - PCB
Type
LMA 1500: Single channel with
dual programmable solid state outputs.
Printed circuit board (pcb) mounted. The
DEFLECTOMETER™ display helps optimize
the proper sensitivity setting to detect
all vehicles including motorcycles. NO
MORE GUESS WORK WHEN SETTING SENSITIVITY
OR FREQUENCY!
• Plug-in compatible with Elite SL3000*
& CSW200* Omniboard models.
• Other industry operators may also be
compatible, please contact EDI for brand
and model number updates.
LMA 400: Single channel series
with dual programmable relay outputs.
Printed circuit board (PCB) mounted. Ten
levels of sensitivity and four loop
frequencies. Supply voltage is 12 Vdc or
24 Vdc. Available with 10 pin male or
female connector |
|
| Complete line of controllers, radio
receivers, transmitters, and accessories for configuring and upgrading
access control systems. Capabilities include telephone entry systems,
radio-based products for remote "keyless entry", "panic" alarms and
greater handicapped access, as well as traditional forms of access
control, such as keypads and swipe card readers.
Contact Up Today!
|
Multi Door Controllers: AM/II | For
creating new stand-alone access control systems or for field expansion
of existing systems.

Item# 95789
an extremely versatile access controller for creation of new stand-alone
access control systems or for field expansion of existing systems. It
offers a wide range of entry options, including a built-in radio for
keyless entry and panic functions. Systems can be easily tailored by
size. Each AM/II controls up to four ports, but can be networked to link
as many as 32. For storage of over 65,000 input devices, names, and
events, modular memory can be upgraded in the field.
All data memory is non-volatile EEPROM with data retention in excess of 10
years. Memory modules are available in four capacities:
AM/II (16): Limited Use - Call Technical Support ( 800.421.1587 press 2)
for application notes.
AM/II (64): 2,000 User / 2,000 Event Capacity
AM/II (128): 5,000 User / 5,000 Event Capacity
AM/II (256): 10,000 User / 5,000 Event Capacity
Features
RS485 networking - up to 8 units, 32 doors.
Extremely flexible access controller with radio receiver for added
convenience of keyless entry.
Allows option of remotely transmitted personal emergency (panic) signal.
Many inputs and accessories for creating stand-alone systems or expanding
existing ones.
Ideal for full range of commercial installations and residential sites
like gated communities.
Controls up to four portals (can be networked to 32).
Supports over 65,000 transmitters, entry codes, and card codes - modular
memory can be upgraded in field.
MegaCode radio format supports over 1,000,000 unique identification codes.
Remote activation from up to 250 feet away.
Real time print log (RS232 output to printer).
Remote and local programming using a personal computer and programming
software.
Block coding for transmitters and cards.
15 security levels, 15 time zones, seven door schedules, and 24 holiday
schedules.
Magic wand support for system maintenance.
Fully supervised obstacle sensing via gate edge transmitter.
Automatic door relock when door sense input is used.
Extensive ESD and lightning protection of all inputs and outputs.
Support for anti-tailgating, timed anti-passback operation.
|
General Specifications
|
|
OUTPUTS
|
|
Relay: |
Four form "C" relays, rated at 3 amps
with programmable output duration; all four can be
configured for open/close; A and B can be supervised for
status; C and D can be configured for control; all relay
contacts have RFI, ARC, and lightning suppression |
|
Wiegand: |
Wiegand compatible signals for adding RF
capability to other access control systems; 26 bit, 30
bit, and 31 bit formats are supported |
|
RS232: |
One port for connection to a local
computer printer, CRT, or modem; all communications are
at 9600 baud |
|
LDC Display: |
Integral 2-line by 24 character backlit
display for local programming and transaction monitoring |
|
LED Indicators: |
Front panel indicators for all input and
output activity for on-site troubleshooting |
|
INPUTS
|
|
RF: |
318 MHz superheterodyne receiver with -90
dBm sensitivity; built-in 20 dBm adjustable attenuator
for fine tuning radio performance |
|
Keypad/Reader: |
Two sets of inputs for connecting up to
six different keypads, card reader interfaces, or
receivers |
|
Open Request: |
Contact closure to ground activates
channel A or B relays |
|
Programming: |
Integral 17-key silicone rubber keypad
for local programming |
|
Access Buttons: |
One button for each of the four relays;
used to manually control relays |
|
POWER |
|
AC: |
14 to 24 V @ 500 mA; 14 V wall mount
transformer included |
|
DC: |
12 to 35 V @ 500 mA |
|
OPERATING
TEMPERATURE
|
|
Electronics: |
-22° to +149° F (-30° to +65° C) |
|
Display: |
0° to +104° F (-18° to +40 C) |
|
MEMORY |
All data memory is non-volatile EEPROM
with data retention in excess of 10 years; modular
design to facilitate easy transfer to another
controller; memory modules available in four capacities |
|
MM16 |
16K capacity, small memory |
|
MM64 |
64K capacity, medium memory |
|
MM128 |
128K capacity, large memory |
|
MM256 |
256K capacity, extra-large memory |
|
CLOCK/CALENDAR |
Built-in-24-hour clock/calendar with
battery backup and daylight savings adjustment |
|
CONNECTIONS |
All wiring connections to the unit are
plug-on, screw terminal blocks |
|
ANTENNAS
|
|
LA |
(order separately) |
|
EXA-1000 |
(order separately) |
|
EXA-2000 |
(order separately) |
|
Literature and Manual |
Software: AccessBase software is an easy-to-use Windows-based package for
networking multiple controllers, remote devices, and portals within
an access control system. It can be used for PC-based control of multiple AM/II
or Telephone Entry controllers (Models AE-1 and AE-2), as well as the portals
and remote devices that they control.
Up to eight controllers can be networked through AccessBase and each controller
can be used to control up to six remote devices (48 in all) and up to four
portals (32 in all). Linear's AM/II multi-door controller and AE-1 or AE-2
telephone entry systems can be programmed via dial up or direct connection using
either AccessBase or Account Manager.
Account Manager is a limited capability Windows based program that allows the
user to perform most functions associated with a single node application.
Account Manager DOES NOT support networking of multiple controls.
|
Item#
95790Remote Proximity Receiver
Features
Convenient, cost-effective, and reliable form of door or entrance control.
2-to-3-inch radio transmitter read range.
Compatible with Linear radio-based access control systems.
2-color status LED indicates "power on" and "access granted".
Installs in a single-gang electrical box.
Prevents transmitter from being detected by wrong receiver.
Literature
and Manual
|
Item#
95793Proximity Card
Literature and Manual
|
Item#
95795Card Reader Interface
Features
For equipping a Linear access control system with one or two Wiegand devices.
Card Reader Interface can be used with up to two 26 or 31-Bit Wiegand input
devices.
Power is supplied by system controller or external source for locally powered
readers.
Literature
and Manual
|
Item#
95797Supervised Gate Edge Transmitter
Features
Industry's only fully supervised model.
Hourly transmission reports status.
Tamper switch triggered if cover is removed.
Lithium battery powered.
Literature
and Manual |
Item#
95799External Modem
Features
Modem for AM/II, AE-1 and AE-2.
Required for remote PC programming.
9600 baud.
Literature and Manuals
|
|
Commercial Telephone Entry: AE-1, AE-2 | Access Controllers for control of
up to 4 portals via touch-tone telephone (full duplex telephone communications)
and keypad entry.
Item#:
9500733
Product Links:
Specifications
Manual 1
Manual 2
Literature
Accessories for use with the AE-2
Models compatible with the AE-2
Features
Ideal for apartments, condos, gated communities, dormitories, offices and
other commercial sites.
Extensive capacity - up to 3,500 users.
Controls up to four portals via touch-tone telephone and keypad entry.
RS485 capability for networking up to 32 doors.
Full duplex telephone communications.
Built-in radio for keyless entry - wireless activation from up to 250 feet
away field.
Programmable directory, talk time, and display message.
Selectable extended talk time.
Accepts inputs from remote keypads, Wiegand cards, and proximity devices.
Programming via built-in keypad or PC software.
Large, vacuum fluorescent display, 2 lines by 20 characters.
Optional sunlight visor and stainless steel post mounting plate.
Can be networked - up to 64 units.
Windows based software for installation management.
|
|
Access Base Programming Software for Telephone Entry (AE-1, AE-2) and
AM/II Controllers. Version 1.52 is now available for downloading. |
Residential Telephone Entry: RE-1N, RE-1G, RE-1SS
|
|
Single Door Controllers: AK-1, AK-2, AKR-1, AM-WOR, AP-4
Item#: 95801
PDF
Specs Single Door Controllers Wireless
Features
Ideal for gated communities, parking facilities, and industrial sites.
Easy to set-up and use — up to 480 remotes can be programmed with a few
keystrokes.
Easy to add, suspend, and delete transmitters through programming mode —
no transmitter dip switches to set.
Supports 480 block coded transmitters or 238 individual
transmitters/wireless keypad entry codes.
Supports one fully supervised safety edge transmitter
|
Accessories: Receivers, Wired Keypads, Wiegand, Specialty, RS-232,
Antennas, Cabinets.
|
|
Bar Code Access Control systems 95779:

|
|
Transmitters: Keychain, Genie Compatible, Visor |
Solar Power for security systems

Pre-assembled & Factory Tested
|
Solar Battery Chargers Notebook - Computers

More Info |
U.S. Government, Military applications

Solar
Battery Charger
More Info |
OkxPower-Flex 1600

electronic generator
More Info |
|
Airport
Lighting UPS

More Info |
UPS LED Traffic
lights

More Info |
Hospital Grade
UPS

More Info |
|
Solar Power DC or solar generator 12, 24, 36, 48VDC Output

More Info
|
Solar Power AC Hybrid Power Station

More Info |
Smart Fuel Cells

More Info |
|
Solar systems for
Home, Commercial and industrial Power.

More Info |
Relief Vehicle

More Info |

More Info |
|
We offer Power Management
with USB Biometric Password rd Manager provide users a convenient and
secure way to manage and access multiple security phrases and codes.
This product biometrically identifies users and gives them convenient
access to password protected applications and web sites. |
IQUPS CommLink
around the
world!
Check the status of your PV-Wind-Fuel Cell plant – from your home, your
office or anywhere you may be. A PC with an internet browser is all that
is needed to access the system.Communications provides complete plant
monitoring, remote diagnosis, data storage and display. It features an
integrated HTTP web interface that allows you to access plant
information via a PC, regardless of operating system or browser type.
IQUPS CommLink the link between the PV plant and its owner. It
combines computing power, storage capacity, and versatile communications
interfaces in a compact enclosure. The data-logger offers up-to-date
display and control options on the internet.
Data transfer and plant configuration via the internet is handled either
by Ethernet connection or telephone modem. Data transfer is automatic –
all you have to do is set the desired intervals.
IQUPS
View communicates PV system status from the IQUPS.com
controller over a broadband or wireless internet connection to a website
for 24/7 access. The website displays real- time and historic data as
well as advance alerts of any potential system problems. All of the
hardware and software is included to enable a simple plug and play
installation. By avoiding expensive site visits, the IQUPS Web View will
reduce the life cycle costs of off-grid PV systems. Battery Bank.
Solar power systems
for hazardous locations are certified Class l Div ll and as such are
approved for use the United States. Systems are engineered to meet the
new International Standard IEC-E60079-15:02 - Electrical apparatus for
explosive gas atmospheres-Part 15:Type of protection n requirements for
solar/battery powered installations
iPhone Secure Remote Control and Visualization protocol |
|
Are you
tired of your devices being left
in the dark, when your solar
energy system stops providing
power? Then SFC Fuel Cells are
the perfect answer for you.
PDF File

|
|
Energy Installation Monitoring and Management Services
 
IQUPs.com Explosionproof UPS backup lighting systems: Explosionproof Lights,
Explosion proof LED Lights, Explosion proof Lights, Solar Explosionproof
LED Lights, Solar LED Explosionproof Lights, LED Explosionproof Lights,
Explosionproof LED Lights, LED Explosion proof Lights, Explosion proof
Fluorescent Lights, Explosionproof Steady-On Lights, Explosion proof
Steady On Lights |
|
Off-grid combined wind and diesel solutions for
island nations, farms, remote areas, cell
towers, exploration equipment, backup power &
water pumps for natural gas mines; rapid
deployment diesel & wind solutions (to include
airdrop) to disaster areas for power to
emergency and medical equipment, water pumps;
on-grid applications for farms, factories,
remote communities; and wind farm deployments.
Available in 3Q 2007/08
|
|
|
|
Some Applications for the SPDC-AC Line of products
Oil and Gas Applications:
RTU/SCADA
Process Control Equipment
Natural Gas Automation
Gas Flow Measurement
Flow metering
Tank Gauging
Cathodic protection
Valve control/actuation
Instrumentation
Seismic monitoring
Telecom/Telemetry:
Data Recording
Microwave repeater sites
BTS base stations
Broadband/spread spectrum radio
VSAT's and gateways
Rural telephony
Two-way radio
Traffic Safety and Control/Transportation Aids:
Message boards
Warning signals
Emergency call boxes
Traffic counters
Intelligent transportation systems
Navigational aids
Lighting
Security:
CCTV and surveillance cameras
Lighting
Perimeter protection
Call boxes
Government Agencies local/Federal/GSA/Military:
Communications
Water pumping
Facility electricity
Remote ranger station power
Area lighting
Emergency backup power
Surveillance
Disaster relief
Rural and Infrastructure Development:
Water delivery
High efficiency refrigeration
Area lighting
Home power systems
Community electrification
Commercial Grid-Tie Power grid-tied:
Office Complexes
Retail Stores
Manufacturing Facilities
Universities
BIPV projects
Features:
- Pre-packaged Systems Available from 7 Watt to 100 Kilowatts
- Experience Integrating & Manufacturing since 1988
- Pre-assembled and Factory Tested
- Outstanding Reliability
- 12, 24 or 48 D/C power
- Class I, Div. II-configured power systems available
- One year warranty
We offer
pre-engineers
Solar Power
Units: basic units
The SPDC-SPAC was designed to be easily expanded; power units can
range from 70 Watts to 100 Kilowatts of Solar, wind, Fuel Cell
generated power. Its flexible platform design
allows it to be easily customized for use with area lighting, remote
communications, security systems, and portable surveillance
equipment, to name a few applications. Charge power alone can be
doubled or tripled with the addition of simple, cost-effective
photovoltaic capture equipment. shipping container-sized unit that
can be trucked or air-dropped to remote areas. |
|
Sun Path for Chart
40 North Latitude
 |
-
abc-tech_SPDC Telecom Sizing.pdf
-
abc-tech_SPDC Traffic Sizing.pdf
IQ Energy Management Data acquisition
We offer design assistance on hourly
basis minimum 3 hours
Daily solar radiation map
|
|
|
Airport and
Heliport landing
back-up Battery Charger: 12Volts,
24 Volts, 36Volts, 48 Volts -120VAC or 230VAC
Using state-of-the-art, switch-mode technology, the DLS Power Supply series
is engineered with the user and variable environmental conditions in mind.
Extra care has been given to insure many years of service-free operation,
even when subjected to extremely harsh conditions. Batteries are charged
quickly and efficiently without over charging and pumps, motors, and fans
operate perfectly for prolonged life.
IOTA Engineering uses advanced switch mode technology to bring to market
highly sophisticated electronic converter/power supplies at appealing
affordability.
Exceptionally clean DC output insures pumps, motors, fans, and lights work
perfectly. This means longer life for any connected load; virtually no AC
ripple to cause static or premature failure of radio or television
equipment.
|
|
Inverter/Charger Available in 12 - 24- and 48-volt models, it provides
utility-grade output power and offers high surge capacity
105 VAC/60 Hz - 105 VAC/50 Hz - 120 VAC/60 Hz - 220 VAC/60 Hz - 230 VAC/50 Hz-DC
to DC Converters
-DC to DC Converters Din Rail
-Din Rail Linear Power Supplies
-DIN Rail power supplies
-Din Rail Single Phase Power Supplies
-Din Rail Unregulated Line Power Supplies
-Din Rail Voltage Regulator
-Inverters Accessories
-Inverters DC/AC
-Mini Power
-Power Supplies
-Power Transformers
-Transformer |
|

Traffic Enclosures and Cabinets |
|
|
|
 |
|
Hot Swappable
IQUPS with NEBS Level 3 Certification

More Info
 |
|
| Complete line of controllers, radio
receivers, transmitters, and accessories for configuring and upgrading
access control systems. Capabilities include telephone entry systems,
radio-based products for remote "keyless entry", "panic" alarms and
greater handicapped access, as well as traditional forms of access
control, such as keypads and swipe card readers. |
Note:
To view the above PDF documents, you will need the
free Adobe Acrobat
Reader
|
|